- Store
- >
- Krautkramer Phasor Series
Krautkramer Phasor Series
SKU:
$2,997.00
$2,997.00
Unavailable
per item
The Phasor series ultrasonic flaw detectors comes available in four different models with upgraded features and benefits. Phasor CV is a code-compliant conventional ultrasonic flaw detector that can be UPGRADED to Phasor 16/16 Weld or to the 16/64 Phasor XS. Upgrading to phased array is a quick and easy software upgrade to Phasor 16/16 Weld or Phasor XS. No changes to the base unit hardware are required and utilizing the same simple menu-driven interface as the Phasor CV model, training is minimal. Combined with phased array transducers, both platforms can solve your most demanding inspection applications in less time at an affordable price.
Phasor 16/16 Weld and Phasor XS can switch to conventional UT quickly so that inspectors can use any standard transducer to evaluate detected flaws (locating and sizing) to any specified standard or test instruction.
The Phasor CV/DM combines a phased array imaging device and a conventional flaw detector into one instrument, with a phased array probe, which allows significant increases confidence in corrosion inspection data
Spectification:
Internal Memory Set-up files
Removable Memory On 512 MB SD Card for report and set-up files
Documentation Format JPEG ~80 KB/image
Weight 3.8 kg (8.2 lbs) with battery
Dimensions 282 mm W x 171 mm H x 159 mm D (11.1 in. W x 6.8 in. H x 6.3 in. D)
Battery Custom Li Ion battery pack - 356P configuration
Battery Life 6 hrs minimum
Battery Charging External charger
External Power Supply Universal input 85 to 260 V AC / 50 to 60 Hz
Probe Connectors Conventional - 00 lemo/BNC adapters provided - Phased Array - Custom ZIF
VGA Output Yes
Dialog Languages Chinese, English, French, German, Italian, Japanese, and Spanish
Display Size 165 mm (6.5 in.) diagonal
Display Resolution VGA color TFT 640H x 480V pixel
Conventional / Phased Array Channel
Conventional Phased Array
Pulser Spike Bi-Polar Square Wave
Pulse Repetition Frequency 15 to 2000 Hz 15 to 7680 Hz
Pulser Voltage 300 V max ± 25 V to ± 75 V (1 V steps)
Pulser Energy Low or High (selectable)
Pulser Rise Time < 15 nsec < 15 nsec
Damping 50 or 1000 Ohms (selectable)
Mode of operation single, dual single
Receiver Input Capacitance < 50 pF
Receiver Input Resistence 1000 Ohms in dual mode 220 Ohms
Maximum Input Voltage 40 V peak-to-peak 200 mV peak-to-peak
Bandwidth/Amplifier Bandpass 0.3 to 15 MHz @ -3dB 0.6 to 6.5 MHz @ -3dB
Filter Selection 1.0, 2.0. 2.25, 4.0, 5.0, 10 and 13 MHz + BB 2.0, 3.0, 4.0, 5.0 MHz, Low Pass 4 MHz, High Pass 5 MHz and Broadband (0.6 to 6.5 MHz)
Rectification Pos HW, Neg HW, FW, and RF Pos HW, Neg HW, FW and RF
Analog Gain 0 to 110 dB 0 to 40 dB
Digital Gain 1 5.8 to 39.9 dB (depending on aperturesize)
Focal Laws User selectable - 128 max
Physical Probe 1 to 64
Virtual Probe 1 to 16
Number of Cycles 1 to 128
Pulser Width @ 1/2 Cycle 20 to 500 nsec
Pulser Delay
0 to 10.24 µ-sec
Receiver Delay
0 to 10.24 µ-sec
Acoustic Velocity 1000 to 16000 m/s
0.0393 to 0.5905 in./µ-sec
1000 to 16000 m/s
0.0393 to 0.5905 in./µ-sec
Minimum Range (steel long)
(steel shear) 0 -14 mm (0.55 inch)
0 - 7.5 mm (0.3 inch)
0 - 7.6 mm (0.3 inch)
0 - 4.2 mm (0.17 inch)
Maximum Range (steel long)
(steel shear) 0 - 14060 mm (553 inch)
0 - 7626 mm (300 inch)
0 - 1073 mm (42 inch)
0 - 1073 mm (42 inch)
Display Delay 2.5 m (98.5 inch)
1 m (39.4 inch)
Auto Timebase Calibration Yes
Reject 0 to 80%
0 to 80%
TCG 15 points @ 6 dB/µ-sec
15 points @ 6 dB/µ-sec
Gates A and B
A, B and IF
Gate Threshold 5 to 95%
5 to 95%
Gate Start 0 mm - full range
0 mm - full range
Gate Width 1 mm - full range
1 mm - full range
Gate Logic Off, Positive, and Negative
(Off, Coincidence, and Anticoincidence)
Off, Positive, and Negative
(Off, Coincidence, and Anticoincidence)
TOF Modes Flank/Peak
Flank/Peak
Scan Type
Linear and Sector
Available Views A-Scan
A-Scan, B-Scan and Sector
Displayed Readings Amplitude, Sound Path, and Trig
Beam, Amplitude, Sound Path,
Trig for displayed and for all beams
Measurement Resolution 5 nsec
5 nsec
Displayed Units of Measurements mm or inch (selectable)
mm or inch (selectable)
Environmental Tests (Per Mil-Std-810F)
Cold Storage -20°C for 72 hrs, 502.4
Procedure I
Cold Operation 0°C for 16 hrs, 502.4
Procedure II
Heat Storage +70°C for 48 hrs, 501.4
Procedure I
Heat Operation +50°C for 16 hrs, 501.4
Procedure II
Damp Heat / Humidity
(storage) 10 Cycles:
10 hrs at +65°C down to
+30°C,
10 hrs at +30°C up to +65°C,
transitions within 2 hrs, 507.4
Temperature Shock 3 Cycles:
4 hrs at –20°C up to +70°C,
4 hrs
at +70°C, transitions within 5
mins.
503.4 Procedure II
Vibration 514.5-5 Procedure I, Annex C,
Figure 6, general exposure:
1 hr each axis
Shock 6 cycles each axis, 15g, 11ms
half sine, 516.5 Procedure I
Loose Cargo 514.5 Procedure II
Transit Drop
(packaged for shipment) 516.5 Procedure IV, 26 drops
IP54 / IEC529 … dust proof / dripping water proof as per
IEC 529 specifications for IP54 classification
Phasor CV/DM Option
Pulser Bi-Polar Square Wave
Pulser Repetition Freq. 15 to 7680 Hz
Pulser Voltage 50 V to 150 Volts 2V Steps
Pulser Rise Time < 15 nsec
Mode of Operation Custom T/R operating files only
Receiver Input Resistance 220 Ohms
Max Input Voltage 200 mV peak-to-peak
Bandwidth/Amplifier
Bandpass 0.6 to 6.5 MHz @ -3 dB
Filter Selection 2.0, 3.0, 4.0, 5.0 MHz, Low Pass 4 MHz, High Pass
5 MHz and Broadband (0.6 to 6.5 MHz)
Rectification Pos HW, Neg HW, FW and RF
Analog Gain 0 to 40 dB
Digital Gain 0 to 53.9 DB depending on APERTURE selection
Virtual Probe 1 to 16 elements
Pulser Width @ 1/2 Cycle 20 to 500 nsec
Pulser Delay 0 to 10.24 µsec
Receiver Delay 0 to 10.24 µsec
Acoustic Velocity 1000 to 16000 m/sec, 0.0393 to 0.5905”/µsec
Steel Min Range Long: 0-7.6 mm (0.3”), Shear: 0-4.2 mm (0.17”)
Steel Max range Long: 0-1073 mm (42”), Shear: 0-1073 mm (42”)
Display Delay 1m (39.4”)
DM T/R Option
TCG 15 points @ 6 dB/µsec
Gates A, B and IF
Gate Threshold 5 to 95%
Gate Start 0 mm - full range
Gate Width 1 mm - full range
Gate Logic Off, Positive and Negative (Off, Coincidence and
Anticoincidence)
TOF Modes Flank/Peak
Available Views ASCAN, BSCAN and TOP VIEW
Displayed Readings Beam, Amplitude, Sound Path, Trig for displayed
and for all beams
Measurement Resolution 5 nsec
Displayed Units mm or inch (selectable)
DM Option Specifications SW 2.27 Corrosion
Measuring modes Zero to GATE crossing, Flank or Peak and Gate to Gate
Calibration 2 point Manual Probe zeroing and material CAL,
probe wear compensation
Measuring V-path correction
Thin Reading Capture
modes Per Beam minimum, Per Scan minimum, Accumulated
minimum and TOPVIEW auto cursor location to minimum
Probe compatability Compatible Probes (as of October 09)
Global PN 1314599 5Mhz 32element 1.5mm pitch
Global PN 1314699 5Mhz 32 element .75mm pitch
Temperature range –29°C (-20°F) to 57°C (135°F)
* See instrument and probe documentation for
important notes.
TOP VIEW Timed, Time Continuous, and encoded
Phasor 16/16 Weld and Phasor XS can switch to conventional UT quickly so that inspectors can use any standard transducer to evaluate detected flaws (locating and sizing) to any specified standard or test instruction.
The Phasor CV/DM combines a phased array imaging device and a conventional flaw detector into one instrument, with a phased array probe, which allows significant increases confidence in corrosion inspection data
Spectification:
Internal Memory Set-up files
Removable Memory On 512 MB SD Card for report and set-up files
Documentation Format JPEG ~80 KB/image
Weight 3.8 kg (8.2 lbs) with battery
Dimensions 282 mm W x 171 mm H x 159 mm D (11.1 in. W x 6.8 in. H x 6.3 in. D)
Battery Custom Li Ion battery pack - 356P configuration
Battery Life 6 hrs minimum
Battery Charging External charger
External Power Supply Universal input 85 to 260 V AC / 50 to 60 Hz
Probe Connectors Conventional - 00 lemo/BNC adapters provided - Phased Array - Custom ZIF
VGA Output Yes
Dialog Languages Chinese, English, French, German, Italian, Japanese, and Spanish
Display Size 165 mm (6.5 in.) diagonal
Display Resolution VGA color TFT 640H x 480V pixel
Conventional / Phased Array Channel
Conventional Phased Array
Pulser Spike Bi-Polar Square Wave
Pulse Repetition Frequency 15 to 2000 Hz 15 to 7680 Hz
Pulser Voltage 300 V max ± 25 V to ± 75 V (1 V steps)
Pulser Energy Low or High (selectable)
Pulser Rise Time < 15 nsec < 15 nsec
Damping 50 or 1000 Ohms (selectable)
Mode of operation single, dual single
Receiver Input Capacitance < 50 pF
Receiver Input Resistence 1000 Ohms in dual mode 220 Ohms
Maximum Input Voltage 40 V peak-to-peak 200 mV peak-to-peak
Bandwidth/Amplifier Bandpass 0.3 to 15 MHz @ -3dB 0.6 to 6.5 MHz @ -3dB
Filter Selection 1.0, 2.0. 2.25, 4.0, 5.0, 10 and 13 MHz + BB 2.0, 3.0, 4.0, 5.0 MHz, Low Pass 4 MHz, High Pass 5 MHz and Broadband (0.6 to 6.5 MHz)
Rectification Pos HW, Neg HW, FW, and RF Pos HW, Neg HW, FW and RF
Analog Gain 0 to 110 dB 0 to 40 dB
Digital Gain 1 5.8 to 39.9 dB (depending on aperturesize)
Focal Laws User selectable - 128 max
Physical Probe 1 to 64
Virtual Probe 1 to 16
Number of Cycles 1 to 128
Pulser Width @ 1/2 Cycle 20 to 500 nsec
Pulser Delay
0 to 10.24 µ-sec
Receiver Delay
0 to 10.24 µ-sec
Acoustic Velocity 1000 to 16000 m/s
0.0393 to 0.5905 in./µ-sec
1000 to 16000 m/s
0.0393 to 0.5905 in./µ-sec
Minimum Range (steel long)
(steel shear) 0 -14 mm (0.55 inch)
0 - 7.5 mm (0.3 inch)
0 - 7.6 mm (0.3 inch)
0 - 4.2 mm (0.17 inch)
Maximum Range (steel long)
(steel shear) 0 - 14060 mm (553 inch)
0 - 7626 mm (300 inch)
0 - 1073 mm (42 inch)
0 - 1073 mm (42 inch)
Display Delay 2.5 m (98.5 inch)
1 m (39.4 inch)
Auto Timebase Calibration Yes
Reject 0 to 80%
0 to 80%
TCG 15 points @ 6 dB/µ-sec
15 points @ 6 dB/µ-sec
Gates A and B
A, B and IF
Gate Threshold 5 to 95%
5 to 95%
Gate Start 0 mm - full range
0 mm - full range
Gate Width 1 mm - full range
1 mm - full range
Gate Logic Off, Positive, and Negative
(Off, Coincidence, and Anticoincidence)
Off, Positive, and Negative
(Off, Coincidence, and Anticoincidence)
TOF Modes Flank/Peak
Flank/Peak
Scan Type
Linear and Sector
Available Views A-Scan
A-Scan, B-Scan and Sector
Displayed Readings Amplitude, Sound Path, and Trig
Beam, Amplitude, Sound Path,
Trig for displayed and for all beams
Measurement Resolution 5 nsec
5 nsec
Displayed Units of Measurements mm or inch (selectable)
mm or inch (selectable)
Environmental Tests (Per Mil-Std-810F)
Cold Storage -20°C for 72 hrs, 502.4
Procedure I
Cold Operation 0°C for 16 hrs, 502.4
Procedure II
Heat Storage +70°C for 48 hrs, 501.4
Procedure I
Heat Operation +50°C for 16 hrs, 501.4
Procedure II
Damp Heat / Humidity
(storage) 10 Cycles:
10 hrs at +65°C down to
+30°C,
10 hrs at +30°C up to +65°C,
transitions within 2 hrs, 507.4
Temperature Shock 3 Cycles:
4 hrs at –20°C up to +70°C,
4 hrs
at +70°C, transitions within 5
mins.
503.4 Procedure II
Vibration 514.5-5 Procedure I, Annex C,
Figure 6, general exposure:
1 hr each axis
Shock 6 cycles each axis, 15g, 11ms
half sine, 516.5 Procedure I
Loose Cargo 514.5 Procedure II
Transit Drop
(packaged for shipment) 516.5 Procedure IV, 26 drops
IP54 / IEC529 … dust proof / dripping water proof as per
IEC 529 specifications for IP54 classification
Phasor CV/DM Option
Pulser Bi-Polar Square Wave
Pulser Repetition Freq. 15 to 7680 Hz
Pulser Voltage 50 V to 150 Volts 2V Steps
Pulser Rise Time < 15 nsec
Mode of Operation Custom T/R operating files only
Receiver Input Resistance 220 Ohms
Max Input Voltage 200 mV peak-to-peak
Bandwidth/Amplifier
Bandpass 0.6 to 6.5 MHz @ -3 dB
Filter Selection 2.0, 3.0, 4.0, 5.0 MHz, Low Pass 4 MHz, High Pass
5 MHz and Broadband (0.6 to 6.5 MHz)
Rectification Pos HW, Neg HW, FW and RF
Analog Gain 0 to 40 dB
Digital Gain 0 to 53.9 DB depending on APERTURE selection
Virtual Probe 1 to 16 elements
Pulser Width @ 1/2 Cycle 20 to 500 nsec
Pulser Delay 0 to 10.24 µsec
Receiver Delay 0 to 10.24 µsec
Acoustic Velocity 1000 to 16000 m/sec, 0.0393 to 0.5905”/µsec
Steel Min Range Long: 0-7.6 mm (0.3”), Shear: 0-4.2 mm (0.17”)
Steel Max range Long: 0-1073 mm (42”), Shear: 0-1073 mm (42”)
Display Delay 1m (39.4”)
DM T/R Option
TCG 15 points @ 6 dB/µsec
Gates A, B and IF
Gate Threshold 5 to 95%
Gate Start 0 mm - full range
Gate Width 1 mm - full range
Gate Logic Off, Positive and Negative (Off, Coincidence and
Anticoincidence)
TOF Modes Flank/Peak
Available Views ASCAN, BSCAN and TOP VIEW
Displayed Readings Beam, Amplitude, Sound Path, Trig for displayed
and for all beams
Measurement Resolution 5 nsec
Displayed Units mm or inch (selectable)
DM Option Specifications SW 2.27 Corrosion
Measuring modes Zero to GATE crossing, Flank or Peak and Gate to Gate
Calibration 2 point Manual Probe zeroing and material CAL,
probe wear compensation
Measuring V-path correction
Thin Reading Capture
modes Per Beam minimum, Per Scan minimum, Accumulated
minimum and TOPVIEW auto cursor location to minimum
Probe compatability Compatible Probes (as of October 09)
Global PN 1314599 5Mhz 32element 1.5mm pitch
Global PN 1314699 5Mhz 32 element .75mm pitch
Temperature range –29°C (-20°F) to 57°C (135°F)
* See instrument and probe documentation for
important notes.
TOP VIEW Timed, Time Continuous, and encoded