  • Krautkramer USLT 2000

Krautkramer USLT 2000

SKU:
$4,890.00
$4,890.00
Unavailable
per item
Features:
The USLT 2000 Series are ultrasonic dialog instrument contained in a PC having exceptional ultrasonic features, wide frequency range (0.5 - 20 MHz) and two gates. Presentation of the A-scans on the PC monitor with a quasi-analog A-scan resolution of up to 635 x 400 pixels and a high refresh rate. Storage of the instrument settings, test results or complete test orders are made in a database. The USLT 2000 Series ultrasonic flaw detectors are widely used throughout the automotive sector for spot weld testing.

PC-based flaw detector
Comes standard as USB, industrial desktop PC or laptop based units.
Spot weld testing function with optional spot weld testing software UltraLOG
Expandable software modules for precision thickness measurement, case depth measurement and FFT analysis

Spectification:
Calibration ranges    min.: 0 - 2.5 mm; 0 - 0.1” (steel) max.: 0 - 9700 mm; 0 - 381” (steel)
Sound velocity range    500 - 15000 m/s; 0.02 - 0.59 “/ms integrated, editable material table
Pulse shift    -10 - 1500 mm; -0.39 - 50” (steel)
Probe delay    0 - 100 µs
Damping    50 ohms / 500 ohms; 1000 ohms with Dual or Through-Transmission modes
Intensity    220 pF / 1 nF
Frequency range    0.5 - 20 MHz (-3 dB); 4 filter ranges
Pulse repetition frequency    1-1000 Hz, automatically or manually adjustable
Gain    110 dB, adjustable in steps of 0.5 / 1 / 2 / 6 dB
Operating modes    Pulse-Echo, Dual, Through-Transmission
Rectification    full-wave, positive half-wave, negative half-wave, RF display (up to 150 mm/5.9” steel)
Suppression    0 - 90 % linear
DAC/TCG    DAC with up to 16 curve points (reference reflectors), dynamic range 37 dB, maximum slope 6 dB/ms; 3 additional curves at adjustable dB distances, can be changed to TCG (Time-Corrected Gain) mode (horizontal recording threshold); meets national and international test specifications
DGS    recording curves for all valid equivalent reflector sizes and probes with DGS capability; setting as DAC or TCG; evaluation in dB related to curve, ERS or class (JIS); sound attenuation and transfer correction; reference reflectors used: backwall, circular disk reflector and side-drilled hole
Monitor gates    2 independent monitor gates, adjustable over the entire maximum calibration range; evaluation on the basis of A-scan at display refresh rate; gate alarm: off, coincidence, anticoincidence; visual and/or acoustic alarm
Distance measurement    individually selectable for each gate at the echo flank or peak, in the RF mode addition-ally at the zero transition of the increasing or decreasing echo flank - initial pulse and measurement point in gate A or B - measuring points: gate B - gate A (differential measurement)
Measurement resolution    sound path / time of flight: up to 12.6 mm: 0.01 mm; otherwise 0.2 % of display width
Amplitude    0.5 % screen height or 0.2 dB
A-scan digitization    1024 x 1024 pixels
Display freeze    static A-scan freeze, dynamic A-scan freeze (peak value, echo dynamics + real-time signal), average freeze via 2 to 32 ultrasonic pulse cycles
Echo comparison    simultaneous display of the currently active signal and a stored A-scan
Outputs    documentation via standard interfaces of the notebook
Inputs    2 analog inputs, e.g. for probe coordinates, digitization with 10 bits each
Dialog languages    German, English, French, Spanish and Italian
Units    mm, inch, µs
Probes    standard and dialog probes (automatic recognition) can be connected
Data storage    database for storing and managing instrument settings, test jobs and test results, including A-scan, DAC and alphanumeric comments, Export to Microsoft Excel; limited only by the hard disk size
Software    operating system: Windows2000/XP; Client-Server interface OLE 2.0; options: UltraWORKS (design tool), FFT (Frequency analyses) EHT (hardening depth), RTM (resonance thickness measurement with 1 µs resolution), UltraLOG (evaluation program for spot weld testing)
Notebook versions (trademarked units)    standard or industrial version (IP 52)
Mains and battery operation    approx. 5 h, depending on the processor workload
Operating temperature    5 °C - 45 °C; 41 °F - 113 °F (standard) 0 °C - 50 °C; 32 °F - 122 °F (industrial)
Dimensions (H x W x D)    63 mm x 300 mm x 230 mm; 2.5” x 12” x 9” (standard) 64 mm x 302 mm x 273 mm; 2.5” x 11.9” x 10.7” (industrial)